Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Rev. colomb. anestesiol ; 49(3): e202, July-Sept. 2021. graf
Article in English | LILACS, COLNAL | ID: biblio-1280178

ABSTRACT

Abstract Introduction: In-line positioning of an ultrasound image provides higher success rates and less time to completion for radial arterial cannulation. But preferable size and distance of ultrasound display has not been previously discussed. Objective: To assess the ideal visual distance and display size when using a smart phone or tablet as the ultrasound image display. Methods: Four smart phones or tablets were used as ultrasound displays in six different configurations in a simulated radial artery puncture. In a questionnaire, 116 anaesthesiologists working in Ibaraki Prefecture, Japan, were asked which of the six configurations was preferable for radial artery cannulation. Results: Sixty anaesthesiologists answered the questionnaire. About half (53%) preferred the smaller display (4- or 5.5-inch) fixed at a distance of 30 to 40 cm, and most of the rest (44%) preferred the larger display (7.9- or 9.7-inch) placed posterior to the probe with a visual distance of 45 to 60 cm. Conclusions: Among the anaesthesiologists, the preferable size and visual distance for ultrasound-guided radial artery cannulation varied using a smart phone or tablet for in-line display.


Resumen Introducción: El posicionamiento en línea con una imagen ecográfica permite mayores tasas de éxito y reduce el tiempo para realizar la canalización de la arteria radial. Sin embargo, no se ha hablado sobre cuál es el tamaño y la distancia preferibles para la imagen en pantalla. Objetivo: Evaluar la distancia visual y el tamaño de la imagen en pantalla cuando se utiliza un teléfono inteligente o una tableta para visualizar la imagen ecográfica. Métodos: Se utilizaron cuatro teléfonos inteligentes o tabletas como pantalla para visualizar las imágenes ecográficas en seis configuraciones distintas, en una simulación de la canalización de la arteria radial. Mediante un cuestionario se preguntó a 116 anestesiólogos que trabajan para la Prefectura de Ibaraki, Japón, cuál de las seis configuraciones era preferible para la canalización de la arteria radial. Resultados: Sesenta anestesiólogos respondieron el cuestionario. Aproximadamente la mitad (53%) prefirieron la imagen más pequeña (4 o 5,5 pulgadas), fija a una distancia de 30 a 40 cm, y la mayoría de los otros (44%) prefirieron la imagen más grande (7,9- o 9,7 pulgadas), colocada en la parte posterior al transductor, con una distancia visual de 45 a 60 cm. Conclusiones: Entre los anestesiólogos, el tamaño preferido y la distancia visual para la canalización de la arteria radial guiada por ecografía, varió utilizando un teléfono inteligente o una tableta para su visualización en línea.


Subject(s)
Humans , Catheterization , Ultrasonography , Radial Artery , Anesthesiologists , Punctures , Prospecting Probe , Smartphone , Methods
2.
Rev. bras. anestesiol ; 67(3): 284-287, Mar.-June 2017. tab, graf
Article in English | LILACS | ID: biblio-843388

ABSTRACT

Abstract Background and objectives: The number of laparoscopic surgeries performed is increasing every year and in most cases the pneumoperitoneum method is used. One alternative is the abdominal wall lifting method and this study was undertaken to evaluate changes of functional residual capacity during the abdominal wall lift procedure. Methods: From January to April 2013, 20 patients underwent laparoscopic cholecystectomy at a single institution. All patients were anesthetized using propofol, remifentanil and rocuronium. FRC was measured automatically by Engstrom Carestation before the abdominal wall lift and again 15 minutes after the start of the procedure. Results: After abdominal wall lift, there was a significant increase in functional residual capacity values (before abdominal wall lift 1.48 × 103 mL, after abdominal wall lift 1.64 × 103 mL) (p < 0.0001). No complications such as desaturation were observed in any patient during this study. Conclusions: Laparoscopic surgery with abdominal wall lift may be appropriate for patients who have risk factors such as obesity and respiratory disease.


Resumo Justificativa e objetivos: O número de cirurgias laparoscópicas feitas tem aumentado a cada ano e, na maioria dos casos, o método com pneumoperitônio é o escolhido. Uma opção é o método de elevação da parede abdominal. Este estudo foi feito para avaliar as alterações da capacidade residual funcional durante o procedimento de elevação da parede abdominal. Métodos: De janeiro a abril de 2013, 20 pacientes foram submetidos à colecistectomia laparoscópica em uma única instituição. Todos foram anestesiados com propofol, remifentanil e rocurônio. A CRF foi medida automaticamente com o Engström Carestation antes da elevação da parede abdominal e, novamente, 15 minutos após o início do procedimento. Resultados: Após elevar a parede abdominal, um aumento significativo foi observado nos valores da capacidade residual funcional (antes da elevação da parede abdominal: 1,48 × 103 mL: após a elevação da parede abdominal: 1,64 × 103 mL) (p <0,0001). Não houve complicações, como dessaturação, em nenhum paciente durante este estudo. Conclusões: A cirurgia laparoscópica com elevador da parede abdominal pode ser apropriada para pacientes com fatores de risco como obesidade e doenças respiratórias.


Subject(s)
Humans , Male , Female , Functional Residual Capacity , Monitoring, Intraoperative/methods , Cholecystectomy, Laparoscopic/methods , Abdominal Wall , Retrospective Studies , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL